Leave Your Message
*Name Cannot be empty!
Enter a Warming that does not meet the criteria!
China PQ2C Double Chamber Vacuum Furnace Factory - Advanced Suppliers for Intelligent Heat Treatment Equipment
Hot Products

China PQ2C Double Chamber Vacuum Furnace Factory - Advanced Suppliers for Intelligent Heat Treatment Equipment

The PQ2C series double chamber vacuum furnace is an advanced piece of intelligent heat treatment equipment designed with a unique independent double chamber structure, comprising a pretreatment chamber and a main treatment chamber. This innovative design optimizes the process flow, making it a preferred choice among manufacturers in China, The pretreatment chamber efficiently integrates vacuuming, preheating, and degreasing functions. It effectively removes volatile substances such as grease and binders from the surface of the workpiece, preventing contamination during high-temperature sintering. The main processing chamber specializes in high-temperature heating (up to 1320 °C) and controlled cooling through gas quenching, ensuring enhanced material densification and performance, This versatile equipment is utilized across various industries, including aerospace, electronic semiconductors, medical equipment, precision manufacturing, metal processing, scientific research, and the development of new materials. It is especially suitable for processing high-value, high-precision parts, significantly improving product yield and batch consistency. With the increasing demand for new materials and precision manufacturing, the applications of the PQ2C vacuum furnace in high-end industries and scientific research will continue to grow. As a leading supplier in China, our factory is committed to delivering exceptional quality and innovative solutions for your heat treatment needs

    CHARACTERISTIC 01

    The pretreatment room and the main processing room are independent temperature control, vacuum isolation, support continuous production, shorten the process cycle

    The pretreatment room is equipped with gradient heating and vacuum degreasing system to accurately decompose organic matter, avoid coking and carbon residue

    A reliable vacuum door is installed between the two rooms to ensure that the pretreatment room is completely separated from the main processing room and that each room does not interfere with each other during processing

    Two-room independent PLC+ industrial computer management, support process parameter linkage programming, data traceability and remote operation and maintenance, reduce operation complexity

    The workpiece can be heated under different vacuum (10-2~10-6 mbar) to avoid surface oxidation and decarbonization and ensure the purity and finish of the material

    Both the pretreatment room and the main processing room adopt multi-zone independent temperature control, combined with PID algorithm, to achieve ±5℃ furnace temperature uniformity, with good temperature control accuracy

    Integrated gas quenching (nitrogen/argon) system in main processing room, combined with high efficiency heat exchanger, significantly improve cooling uniformity, adapt to different material characteristics

    Integrated PLC, with program controller or computer interface, touch screen, recorder and other real-time monitoring furnace vacuum degree, temperature, pressure and other data, support remote fault diagnosis and process tracing

    COMMON SPECIFICATIONS 02

    Parameter Specification Details
    Model number PQ2C-2000
    Effective working area dimension: Width × height × length (mm) 1000×1000×1400
    Temperature Maximum 1320℃ / normal operating temperature 540~1280℃
    Cooling pressure 0.87 to 2.8 bar abs (optional)
    Handling weight approx. (Kg) 2000
    Installed power (KW) 500

    Frequently Asked Questions FAQ

    How does the two-room design improve production efficiency?

    The pretreatment room and the main processing room feature independent temperature control and vacuum isolation. This allows for continuous production cycles, significantly shortening the overall processing time.

    How is organic contamination prevented during pretreatment?

    The pretreatment room is equipped with a gradient heating and vacuum degreasing system. This setup accurately decomposes organic matter, preventing coking and carbon residue on workpieces.

    What vacuum levels can be achieved to prevent surface oxidation?

    Workpieces can be heated under vacuum levels ranging from 10-2 to 10-6 mbar. This high-vacuum environment effectively prevents surface oxidation and decarburization, ensuring material purity.

    What is the temperature uniformity of this furnace?

    Both chambers utilize multi-zone independent temperature control combined with advanced PID algorithms, achieving a highly uniform furnace temperature of ±5℃.

    What cooling system is integrated into the PQ2C-2000?

    The main processing room integrates a gas quenching system (using nitrogen or argon) paired with a high-efficiency heat exchanger to optimize cooling uniformity across different material types.