China VCQ Vacuum High Pressure Gas Quenching Furnace | Suppliers and Factory for High Precision Metal Workpieces
characteristic
01The workpiece can be heated under different vacuum (10-2~10-6 mbar) to avoid surface oxidation and decarbonization and ensure the purity and finish of the material.
Multi-zone independent temperature control, combined with PID algorithm, to achieve ±5℃ furnace temperature uniformity, with good temperature control accuracy.
Through different cooling inert gas (nitrogen, argon) and under different cooling pressure, combined with high-speed, large flow fan to quickly cool the workpiece, cooling speed is controllable.
Can choose the cooling gas flow direction and air flow reversal time, combined with high efficiency heat exchanger, significantly improve the cooling uniformity, reduce the thermal stress deformation of parts.
The heating chamber is made of graphite composite material or all-metal structure (such as molybdenum heating elements and metal heat insulation screen), which is resistant to high temperature and high pressure airflow and has long service life.
Different shapes of heating chamber can be selected to support square structure or round structure.
Choose a flexible opening method of the furnace door according to the customer's on-site requirements (such as the door position left and right direction, automatic or manual opening).
Integrated PLC, with program controller or computer interface, touch screen, recorder and other real-time monitoring furnace vacuum degree, temperature, pressure and other data, support remote fault diagnosis and process tracing.
Heating chamber types are available
02
Common specifications
03| Model number | VCQ-50 | VCQ-200 | VCQ-600 | VCQ-1000 | VCQ-1500 | VCQ-2000 |
| Effective working area dimension Width × height × length (mm) |
300×300×500 | 400×400×600 | 600×600×900 | 800×800×1200 | 900×900×1200 | 1000×1000×1500 |
| Working vacuum | 10-1~10-6 mbar (optional) | |||||
| Temperature | Max. 1350℃ / Normal operating temperature 150~1300 ℃ (optional) | |||||
| Heating chamber type | Square heating chamber, round heating chamber, round metal molybdenum heating chamber (optional) | |||||
| Cooling gas medium | Nitrogen, Argon (optional) | |||||
| Gas cooling pressure | 0.87~10 barabs (optional) | |||||
| Handling weight approx. (Kg) | 50 | 200 | 600 | 1000 | 1500 | 2000 |
| Installed power (KW) | 80 | 110 | 160 | 300 | 380 | 450 |
Frequently Asked Questions
04The equipment can operate under different working vacuum levels ranging from 10-1 to 10-6 mbar (typically 10-2~10-6 mbar), preventing surface oxidation and decarburization to preserve raw material purity and superior surface finish.
It uses multi-zone independent temperature control paired with an advanced PID algorithm, maintaining furnace temperature uniformity within ±5℃ for accurate thermal processing.
Users can select from square, round, or round metal molybdenum structures. Materials include graphite composite options and all-metal designs with molybdenum heating elements and metal heat insulation screens.
Cooling speed and uniformity are regulated using inert gas (nitrogen or argon) under controllable pressure (0.87~10 barabs), reversible air flow direction timing, a high-speed high-flow fan, and high-efficiency heat exchangers.
An integrated PLC setup with a touchscreen controller or computer interface records real-time vacuum levels, temperatures, and pressures, while supporting remote fault diagnostics and complete process traceability.
Standard models range from VCQ-50 (50 kg capacity, 300×300×500 mm working volume) up to VCQ-2000 (2000 kg capacity, 1000×1000×1500 mm working volume) to accommodate various batch production sizes.