China Suppliers VTL Top Charging Vertical Vacuum Furnace Factory for Precise Heat Treatment of Workpieces
Characteristics
01Electric or hydraulic drive furnace cover lifting, with a special lifting system, heavy workpieces quickly and smoothly into the furnace, reduce the risk of manual intervention and bump.
Heating the workpiece under different vacuum degree (10-2~10-6 mbar) to avoid surface oxidation and decarbonization and ensure pure and stable process environment.
Multi-zone independent temperature control, combined with PID algorithm, to achieve ±5℃ furnace temperature uniformity, with good temperature control accuracy, to meet the needs of large workpiece consistency processing.
The heating chamber is made of graphite composite material or all-metal structure (such as molybdenum heating elements and metal heat insulation screen), which is resistant to high temperature and high pressure airflow and has long service life.
Through different cooling inert gas (nitrogen, argon, helium) and under different cooling pressure, combined with high speed and large flow fan to quickly cool the workpiece, cooling speed is controllable.
Can choose the cooling gas flow direction and air flow reversal time, combined with high efficiency heat exchanger, significantly improve the cooling uniformity, reduce the thermal stress deformation of parts.
Enhanced furnace structure + multiple safety protection, in line with international safety standards, equipment life of more than 20 years.
Integrated PLC, with program controller or computer interface, touch screen, recorder and other real-time monitoring furnace vacuum degree, temperature, pressure and other data, support remote fault diagnosis and process tracing.
Common Specifications
02| Model number | VTL-630 | VTL-860 |
| Effective working area diameter × height (mm) | 600×3000 | 800×6000 |
| Working vacuum | 10-1~10-6 mbar (optional) | |
| Temperature | Maximum 1320℃ / normal operating temperature 540~1280℃ | |
| Cooling gas medium | Nitrogen, Argon (optional) | |
| Cooling pressure | 0.87~10 bar abs | |
| Handling weight approx. (Kg) | 600 | 1000 |
| Installed power (KW) | 240 | 600 |
Frequently Asked Questions
03Q: What are the standard dimensions and loading capacities of the VTL series?
The VTL-630 offers an effective zone of 600×3000 mm with a 600 kg loading capacity, while the VTL-860 provides 800×6000 mm with an approximate handling capacity of 1000 kg.
Q: What is the operating temperature range and temperature uniformity?
The system reaches a maximum temperature of 1320℃ with a standard operating temperature of 540~1280℃. Multi-zone independent PID temperature control achieves ±5℃ uniformity.
Q: Which cooling media and gas pressures can be configured?
The cooling system supports Nitrogen, Argon, and Helium inert gases under controllable pressures ranging from 0.87 to 10 bar abs, with selectable gas flow directions to minimize thermal stress deformation.
Q: What heating chamber materials are available?
The heating chamber can be configured with either graphite composite materials or an all-metal structure featuring molybdenum heating elements and metal heat insulation shields.
Q: Are custom chamber dimensions and technical specifications supported?
Yes, the furnace effective working area dimensions, ultimate vacuum degree (10⁻¹ to 10⁻⁶ mbar), maximum temperature, and gas cooling pressures can be customized according to specific production requirements.
Q: How is the furnace monitored and controlled during operation?
The unit integrates PLC control with a touch screen or PC interface, providing real-time data tracking for vacuum levels, temperatures, and pressures, along with remote diagnosis and complete process traceability.